switch# sh closwitch# sh clock
07:12:59.258 UTC Fri Mar 15 2024
Time source is NTP
switch#
switch# sh inv
NAME: "Chassis", DESCR: "Nexus9000 C93180YC-FX Chassis"
PID: N9K-C93180YC-FX , VID: V07 , SN: FLM261600EA
NAME: "Slot 1", DESCR: "48x10/25G/32G + 6x40/100G Ethernet/FC Module"
PID: N9K-C93180YC-FX , VID: V07 , SN: FLM261600EA
NAME: "Power Supply 1", DESCR: "Nexus9000 C93180YC-FX Chassis Power Supply"
PID: NXA-PAC-500W-PE , VID: V01 , SN: LIT2609AMT2
NAME: "Power Supply 2", DESCR: "Nexus9000 C93180YC-FX Chassis Power Supply"
PID: NXA-PAC-500W-PE , VID: V01 , SN: LIT2609AMVC
NAME: "Fan 1", DESCR: "Nexus9000 C93180YC-FX Chassis Fan Module"
PID: NXA-FAN-30CFM-F , VID: V01 , SN: N/A
NAME: "Fan 2", DESCR: "Nexus9000 C93180YC-FX Chassis Fan Module"
PID: NXA-FAN-30CFM-F , VID: V01 , SN: N/A
NAME: "Fan 3", DESCR: "Nexus9000 C93180YC-FX Chassis Fan Module"
PID: NXA-FAN-30CFM-F , VID: V01 , SN: N/A
NAME: "Fan 4", DESCR: "Nexus9000 C93180YC-FX Chassis Fan Module"
PID: NXA-FAN-30CFM-F , VID: V01 , SN: N/A
switch#
switch# sh env aswitch# sh env aswitch# sh env aswitch# sh env
fan power temperature
switch# sh env
Fan:
---------------------------------------------------------------------------
Fan Model Hw Direction Status
---------------------------------------------------------------------------
Fan1(sys_fan1) NXA-FAN-30CFM-F -- back-to-front Ok
Fan2(sys_fan2) NXA-FAN-30CFM-F -- back-to-front Ok
Fan3(sys_fan3) NXA-FAN-30CFM-F -- back-to-front Ok
Fan4(sys_fan4) NXA-FAN-30CFM-F -- back-to-front Ok
Fan_in_PS1 -- -- back-to-front Ok
Fan_in_PS2 -- -- back-to-front Ok
Fan Zone Speed: Zone 1: 0xb3
Fan Air Filter : NotSupported
Power Supply:
Voltage: 12 Volts
Power Actual Actual Total
Supply Model Output Input Capacity Status
(Watts ) (Watts ) (Watts )
------- ---------- --------------- ------ ---------- --------------------
1 NXA-PAC-500W-PE 63 W 77 W 500 W Ok
2 NXA-PAC-500W-PE 72 W 85 W 500 W Ok
Power Usage Summary:
--------------------
Power Supply redundancy mode (configured) PS-Redundant
Power Supply redundancy mode (operational) PS-Redundant
Total Power Capacity (based on configured mode) 500.00 W
Total Grid-A (first half of PS slots) Power Capacity 500.00 W
Total Grid-B (second half of PS slots) Power Capacity 500.00 W
Total Power of all Inputs (cumulative) 1000.00 W
Total Power Output (actual draw) 135.00 W
Total Power Input (actual draw) 162.00 W
Total Power Allocated (budget) N/A
Total Power Available for additional modules N/A
Temperature:
--------------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
--------------------------------------------------------------------
1 FRONT 80 70 25 Ok
1 BACK 70 42 23 Ok
1 CPU 90 80 35 Ok
1 Homewood 110 90 43 Ok
switch#
switch# sh liceswitch# sh license aswitch# sh license aswitch# sh license aswitch# sh license
brief default feature file host-id tech usage
switch# sh license switch# sh env switch# sh license usswitch# sh license usage
Feature Ins Lic Status Expiry Date Comments
Count
--------------------------------------------------------------------------------
N9K_LIC_1G No - Unused -
VPN_FABRIC No - Unused -
NXOS_OE_PKG No - Unused -
FCOE_NPV_PKG No - Unused -
SECURITY_PKG No - Unused -
ACI-PREMIER-GF No - Unused -
N9K_UPG_EX_10G No - Unused -
TP_SERVICES_PKG No - Unused -
NXOS_ADVANTAGE_GF No - Unused -
NXOS_ADVANTAGE_M4 No - Unused -
NXOS_ADVANTAGE_XF No - Unused -
NXOS_ESSENTIALS_GF No - Unused -
NXOS_ESSENTIALS_M4 No - Unused -
NXOS_ESSENTIALS_XF No - Unused -
NXOS_ESSENTIALS_XM No - Unused -
SAN_ENTERPRISE_PKG No - Unused -
PORT_ACTIVATION_PKG No 0 Unused -
NETWORK_SERVICES_PKG No - Unused -
NXOS_ADVANTAGE_M8-16 No - Unused -
NXOS_ESSENTIALS_M8-16 No - Unused -
FC_PORT_ACTIVATION_PKG No 0 Unused -
LAN_ENTERPRISE_SERVICES_PKG No - Unused -
--------------------------------------------------------------------------------
switch#
switch# sh ver
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (C) 2002-2019, Cisco and/or its affiliates.
All rights reserved.
The copyrights to certain works contained in this software are
owned by other third parties and used and distributed under their own
licenses, such as open source. This software is provided "as is," and unless
otherwise stated, there is no warranty, express or implied, including but not
limited to warranties of merchantability and fitness for a particular purpose.
Certain components of this software are licensed under
the GNU General Public License (GPL) version 2.0 or
GNU General Public License (GPL) version 3.0 or the GNU
Lesser General Public License (LGPL) Version 2.1 or
Lesser General Public License (LGPL) Version 2.0.
A copy of each such license is available at
http://www.opensource.org/licenses/gpl-2.0.php and
http://opensource.org/licenses/gpl-3.0.html and
http://www.opensource.org/licenses/lgpl-2.1.php and
http://www.gnu.org/licenses/old-licenses/library.txt.
Software
BIOS: version 05.45
NXOS: version 9.3(3)
BIOS compile time: 07/05/2021
NXOS image file is: bootflash:///nxos.9.3.3.bin
NXOS compile time: 12/22/2019 2:00:00 [12/22/2019 14:00:37]
Hardware
cisco Nexus9000 C93180YC-FX Chassis
Intel(R) Xeon(R) CPU D-1528 @ 1.90GHz with 32827216 kB of memory.
Processor Board ID FLM261600EA
Device name: switch
bootflash: 115805708 kB
Kernel uptime is 0 day(s), 0 hour(s), 10 minute(s), 16 second(s)
Last reset at 646415 usecs after Fri Mar 15 07:06:21 2024
Reason: Module PowerCycled
System version:
Service: HW check by card-client
plugin
Core Plugin, Ethernet Plugin
Active Package(s):
switch#
switch# sh run
!Command: show running-config
!Running configuration last done at: Fri Mar 15 07:10:50 2024
!Time: Fri Mar 15 07:13:39 2024
version 9.3(3) Bios:version 05.45
vdc switch id 1
limit-resource vlan minimum 16 maximum 4094
limit-resource vrf minimum 2 maximum 4096
limit-resource port-channel minimum 0 maximum 511
limit-resource u4route-mem minimum 248 maximum 248
limit-resource u6route-mem minimum 96 maximum 96
limit-resource m4route-mem minimum 58 maximum 58
limit-resource m6route-mem minimum 8 maximum 8
no password strength-check
username admin password 5 $5$akMtC5Ix$x8tnBcViq.Nj78WbaTNwPQahJJIbu64uZzVCZjky4TC role network-admin
ip domain-lookup
copp profile strict
snmp-server user admin network-admin auth md5 0x53e0bc2403537420da11beb8f907913b priv 0x53e0bc2403537420da11beb8f907913b localizedkey
rmon event 1 description FATAL(1) owner PMON@FATAL
rmon event 2 description CRITICAL(2) owner PMON@CRITICAL
rmon event 3 description ERROR(3) owner PMON@ERROR
rmon event 4 description WARNING(4) owner PMON@WARNING
rmon event 5 description INFORMATION(5) owner PMON@INFO
vlan 1
vrf context management
ip route 0.0.0.0/0 10.109.112.30
interface Ethernet1/1
interface Ethernet1/2
interface Ethernet1/3
interface Ethernet1/4
interface Ethernet1/5
interface Ethernet1/6
interface Ethernet1/7
interface Ethernet1/8
interface Ethernet1/9
interface Ethernet1/10
interface Ethernet1/11
interface Ethernet1/12
interface Ethernet1/13
interface Ethernet1/14
interface Ethernet1/15
interface Ethernet1/16
interface Ethernet1/17
interface Ethernet1/18
interface Ethernet1/19
interface Ethernet1/20
interface Ethernet1/21
interface Ethernet1/22
interface Ethernet1/23
interface Ethernet1/24
interface Ethernet1/25
interface Ethernet1/26
interface Ethernet1/27
interface Ethernet1/28
interface Ethernet1/29
interface Ethernet1/30
interface Ethernet1/31
interface Ethernet1/32
interface Ethernet1/33
interface Ethernet1/34
interface Ethernet1/35
interface Ethernet1/36
interface Ethernet1/37
interface Ethernet1/38
interface Ethernet1/39
interface Ethernet1/40
interface Ethernet1/41
interface Ethernet1/42
interface Ethernet1/43
interface Ethernet1/44
interface Ethernet1/45
interface Ethernet1/46
interface Ethernet1/47
interface Ethernet1/48
interface Ethernet1/49
interface Ethernet1/50
interface Ethernet1/51
interface Ethernet1/52
interface Ethernet1/53
interface Ethernet1/54
interface mgmt0
vrf member management
ip address 10.109.112.25/27
line console
line vty
boot nxos bootflash:/nxos.9.3.3.bin
switch#
switch# dir
4096 Apr 22 13:28:29 2022 .rpmstore/
4096 Apr 22 13:28:52 2022 .swtam/
1738 Apr 22 13:30:12 2022 20220422_133007_poap_7308_init.log
1738 Apr 22 13:43:57 2022 20220422_134352_poap_6851_init.log
308354 Oct 12 02:40:44 2022 20221012_020952_poap_6722_init.log
43900 Mar 15 07:10:28 2024 20240315_070734_poap_7649_init.log
1777998029 Apr 22 13:34:02 2022 aci-n9000-dk9.14.1.2g.bin
4096 Apr 22 13:28:54 2022 eem_snapshots/
4096 Apr 22 13:38:21 2022 home/
47861760 Dec 22 14:18:51 2019 isan_bin.img
28008448 Dec 22 14:18:56 2019 isan_bin_eth.img
54427648 Dec 22 14:18:46 2019 isan_lib.img
7987200 Dec 22 14:18:53 2019 isan_lib_eth.img
4096 Apr 22 13:34:36 2022 lost+found/
1688180224 Apr 22 13:32:49 2022 nxos.9.3.3.bin
0 Apr 22 13:31:21 2022 platform-sdk.cmd
17813 Mar 15 07:10:12 2024 poap_retry_debugs.log
4096 Apr 22 13:29:16 2022 scripts/
4096 Apr 22 13:30:10 2022 virt_strg_pool_bf_vdc_1/
4096 Apr 22 13:29:19 2022 virtual-instance/
59 Mar 15 07:06:35 2024 virtual-instance.conf
Usage for bootflash://
3848171520 bytes used
112741040128 bytes free
116589211648 bytes total
switch#
switch#
switch# sh vlan
VLAN Name Status Ports
---- -------------------------------- --------- -------------------------------
1 default active
VLAN Type Vlan-mode
---- ----- ----------
1 enet CE
Remote SPAN VLANs
-------------------------------------------------------------------------------
Primary Secondary Type Ports
------- --------- --------------- -------------------------------------------
switch#
switch# sh swswitch# sh sw
switch-profile switching-mode switchname
switch# sh switch
^
% Ambiguous command at '^' marker.
switch# switch# sh switchnaswitch# sh switchname
switch
switch#